170 Individual wiring manifold Sub base porting Direct mount type/DIN rail mount type M4GB1·2·3/M4GB1·2·3-D Series • Applicable cylinder bore size: 20 to 100 mm Manifold common specifications Descr ipt ions Manifold type Installation method Air supply/exhaust air method Pilot exhaust air method Piping direction Working fluid Valve and solenoid type Min. working pressure MPa Max. working pressure MPa Withstanding pressure MPa Ambient temperature °C Fluid temperature °C Manual override Lubrication Note 1 Protection structure Note 2 Vibration/impact m/s2 Working environment Note 1. For…
File type: application/pdf
Referenced at:
Ending 27 Ending C yl in de r sw itc h E Series Heat resistance SCA2-L2T (E0), SSD-T1L (ET0) Application cylinder Applications Load voltage Load current Internal voltage drop Leakage current Light Conduit Lead wire Insulation resistance Withstand voltage Maximum shock resistance Ambient temperature Protective structure Weight Descriptions Reed 2 wire E0 ET0 Relay, programmable controller 0mA LED (ON lighting) 100M and over with 500 VDC megger 294m/s2 IEC standards IP67, JIS C0920 (water tight type), oil resistance 12/24 VDC 5 to 50mA 110 VAC 7 to 20mA 12/24 VDC 5 to 50mA 110 VAC 7 to 20mA 220…
File type: application/pdf
Referenced at:
Ending 27 Ending C yl in de r sw itc h E Series Heat resistance SCA2-L2T (E0), SSD-T1L (ET0) Application cylinder Applications Load voltage Load current Internal voltage drop Leakage current Light Conduit Lead wire Insulation resistance Withstand voltage Maximum shock resistance Ambient temperature Protective structure Weight Descriptions Reed 2 wire E0 ET0 Relay, programmable controller 0mA LED (ON lighting) 100M and over with 500 VDC megger 294m/s2 IEC standards IP67, JIS C0920 (water tight type), oil resistance 12/24 VDC 5 to 50mA 110 VAC 7 to 20mA 12/24 VDC 5 to 50mA 110 VAC 7 to 20mA 220…
File type: application/pdf
Referenced at:
www.thomsonlinear.com Motorised Lead Screws Stepper Motor Linear Actuator 2 www.thomsonlinear.com/mls Motorised Lead Screws Precision engineered to be compact, powerful, quiet and efficient New Motorised Lead Screws from Thomson combine a hybrid stepper motor and a precision lead screw together in one compact envelope. Patent-pending Taper-Lock technology allows quick decoupling and secure, properly aligned connections. This combination offers several advantages over a traditional solution. Increased Torque Density Thomson Motorised Lead Screws offer increased torque density over alternative…
File type: application/pdf
Referenced at:
www.thomsonlinear.com Motorised Lead Screws Stepper Motor Linear Actuator 2 www.thomsonlinear.com/mls Motorised Lead Screws Precision engineered to be compact, powerful, quiet and efficient New Motorised Lead Screws from Thomson combine a hybrid stepper motor and a precision lead screw together in one compact envelope. Patent-pending Taper-Lock technology allows quick decoupling and secure, properly aligned connections. This combination offers several advantages over a traditional solution. Increased Torque Density Thomson Motorised Lead Screws offer increased torque density over alternative…
File type: application/pdf
Referenced at:
3D d ra w in gs a va ila bl e at w w w .v uo to te cn ic a. ne t 4.24 GAS-NPT thread adapters available at page 1.117 Conversion ratio: inch = ; pounds = = 25.4 453.6 0.4536 mm g Kg SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES WITH 2 ELECTRIC COILS Art. A Max. capacity Vacuum level Reaction time Ø Passage Servo-control Weight mbar abs. msec section pressure Ø cum/h min max exc. deexc. orifice mm2 bar (g) Kg 07 01 51 G1/4” 6 1000 0.5 16 27 8.5 56.8 4 ÷ 7 0.59 07 02 51 G3/8” 10 1000 0.5 16 27 11.5 103.8 4 ÷ 7 0.58 Note: Coils and connectors are not integral part of the solenoid valves,…
File type: application/pdf
Referenced at:
3D d ra w in gs a va ila bl e at w w w .v uo to te cn ic a. ne t 4.24 GAS-NPT thread adapters available at page 1.117 Conversion ratio: inch = ; pounds = = 25.4 453.6 0.4536 mm g Kg SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES WITH 2 ELECTRIC COILS Art. A Max. capacity Vacuum level Reaction time Ø Passage Servo-control Weight mbar abs. msec section pressure Ø cum/h min max exc. deexc. orifice mm2 bar (g) Kg 07 01 51 G1/4” 6 1000 0.5 16 27 8.5 56.8 4 ÷ 7 0.59 07 02 51 G3/8” 10 1000 0.5 16 27 11.5 103.8 4 ÷ 7 0.58 Note: Coils and connectors are not integral part of the solenoid valves,…
File type: application/pdf
Referenced at:
DuroTec® Gear Pumps DT DuroTec® Gear Pumps DT for abrasive and poor lubricating fluids. In the year 1990, KRACHT initiated the development of Gear Pumps for abrasive and poor lubricating fluids. Since then, this development has been subsequently improved. The limit of applications of Gear Pumps has been reached when the transfer medium does not have the required lubricity for a proper function of the pump and a high working pressure is needed at the same time. Such problematic fluids are for example silicates (sodium silicate), isocyanates and polyols with hard fillers as can be found in the…
File type: application/pdf
Referenced at:
DuroTec® Gear Pumps DT DuroTec® Gear Pumps DT for abrasive and poor lubricating fluids. In the year 1990, KRACHT initiated the development of Gear Pumps for abrasive and poor lubricating fluids. Since then, this development has been subsequently improved. The limit of applications of Gear Pumps has been reached when the transfer medium does not have the required lubricity for a proper function of the pump and a high working pressure is needed at the same time. Such problematic fluids are for example silicates (sodium silicate), isocyanates and polyols with hard fillers as can be found in the…
File type: application/pdf
Referenced at:
3D d ra w in gs a va ila bl e at w w w .v uo to te cn ic a. ne t 5.12 GAS-NPT thread adapters available at page 1.117 Conversion ratio: inch = ; pounds = = 25.4 453.6 0.4536 mm g Kg Filtering cartridge Seal Seal FC SUCTION FILTRES WITH PAPER CARTRIDGE Art. d A B C D E F Max capacity Spare Spare Weight cartridge sealing kit Ø Ø cum/h art. art. g FC 10 G3/8” 79 70 9 72 49 37 15 00 FC 04 00 KIT FC 10 352 FC 20 G1/2” 93 80 13 96 67 51 30 00 FC 08 00 KIT FC 20 774 FC 25 G3/4” 93 80 13 96 67 51 50 00 FC 08 00 KIT FC 25 734 These filtres have been designed to allow vacuum pumps to operate even in…
File type: application/pdf
Referenced at: