P RO D U C T O VE RV IE W INDUSTRIAL HYDRAULICS 2 PU M PS G EA R PU M PS ■ ■FEATURES ++ ROTATION: R clockwise - L counterclockwise MOUNTING FLANGE+SHAFT END: 4 holes and tapered shaft end 1:8 9 HYDRAULIC CONNECTIONS: FE european anged - B BSP threaded ports OTHER: see catalogue for TANDEM and MULTIPLE PUMPS MODEL CODE GPA* - external gear CATALOGUE 11 102 PUMP SIZE DISPLACEMENT FLOW RATE at 1500 rpm CONTINUOUS OPERATING PRESSURE MAX ROTATION SPEED [cm3/rev] [l/min] [bar] [rpm] GPA1 010 1 1.5 250 4000 015 1.5 2.2 260 019 1.9 2.9 025 2.5 3.8 031 3.1 4.7 038 3.8 5.7 047 4.7 7.1 240 053 5.3 8.0…
File type: application/pdf
Referenced at:
S TOOLholder Production Machinery (1898) G S Das TOOLholder-Programm nach SUHNER-Erfahrungen Die richtige Auswahl von den Bearbeitungs- einheiten angepassten Werkzeugspann- elementen ist sehr wichtig, um optimale spanabhebende Bearbeitungsoperationen zu realisieren und eine lange Standzeit der Schneidwerkzeuge zu erhalten. In diesem Bereich besitzt SUHNER einma- lige Erfahrungen, da sie sowohl Bearbei- tungseinheiten als auch Werkzeugmaschi- nen konzipiert und herstellt. Dies erlaubt SUHNER, ein umfassendes Sortiment an Werkzeughaltern und Zubehörteilen anzubieten, die bestens zu den in diesem…
File type: application/pdf
Referenced at:
20 Read the precautions on pages 7 to 12 in the introduction before use. Subject to Export Trade Control Ordinances Air-operated valve for chemical liquids Orifice: Ø14.7 to Ø16 AMD41232 Series Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Cv value Bypass orifice (when bypass is installed) Operation section Chemical liquids, pure water (Note 1) 5 to 90 (5 to 160) (Note 5)…
File type: application/pdf
Referenced at:
20 Read the precautions on pages 7 to 12 in the introduction before use. Subject to Export Trade Control Ordinances Air-operated valve for chemical liquids Orifice: Ø14.7 to Ø16 AMD41232 Series Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Cv value Bypass orifice (when bypass is installed) Operation section Chemical liquids, pure water (Note 1) 5 to 90 (5 to 160) (Note 5)…
File type: application/pdf
Referenced at:
20 Read the precautions on pages 7 to 12 in the introduction before use. Subject to Export Trade Control Ordinances Air-operated valve for chemical liquids Orifice: Ø14.7 to Ø16 AMD41232 Series Specifications Internal structure and parts list Working fluid Fluid temperature Withstanding pressure Working pressure range (A —> B) Working pressure range (B —> A) Valve seat leakage Back pressure Ambient temperature Frequency Installation attitude Connection Orifice Cv value Bypass orifice (when bypass is installed) Operation section Chemical liquids, pure water (Note 1) 5 to 90 (5 to 160) (Note 5)…
File type: application/pdf
Referenced at:
Discrete direct acting 2 port solenoid valve for compressed air, manifold (special purpose valve) FAB Series NC (normally closed) type, NO (normally open) type Port size: M5, Rc1/8 to Rc1/2 26 Refer to Ending 17 for more details. Common specifications Descriptions Compressed air 0 to 1.4 (Refer to the maximum working pressure differential on the individual specifications) 2.1 (1.5 for FAB11/21) AC: -10 to 60, DC: -10 to 40 (no freezing) AC: -20 to 60, DC: -20 to 40 B No corrosive gas and flammable Direct acting poppet structure 0.2 or less Free IP65 or equivalent (Note 1) 1 1.5 1.5 2 2 3 5 3 4…
File type: application/pdf
Referenced at:
Discrete direct acting 2 port solenoid valve for compressed air, manifold (special purpose valve) FAB Series NC (normally closed) type, NO (normally open) type Port size: M5, Rc1/8 to Rc1/2 26 Refer to Ending 17 for more details. Common specifications Descriptions Compressed air 0 to 1.4 (Refer to the maximum working pressure differential on the individual specifications) 2.1 (1.5 for FAB11/21) AC: -10 to 60, DC: -10 to 40 (no freezing) AC: -20 to 60, DC: -20 to 40 B No corrosive gas and flammable Direct acting poppet structure 0.2 or less Free IP65 or equivalent (Note 1) 1 1.5 1.5 2 2 3 5 3 4…
File type: application/pdf
Referenced at:
Discrete direct acting 2 port solenoid valve for compressed air, manifold (special purpose valve) FAB Series NC (normally closed) type, NO (normally open) type Port size: M5, Rc1/8 to Rc1/2 26 Refer to Ending 17 for more details. Common specifications Descriptions Compressed air 0 to 1.4 (Refer to the maximum working pressure differential on the individual specifications) 2.1 (1.5 for FAB11/21) AC: -10 to 60, DC: -10 to 40 (no freezing) AC: -20 to 60, DC: -20 to 40 B No corrosive gas and flammable Direct acting poppet structure 0.2 or less Free IP65 or equivalent (Note 1) 1 1.5 1.5 2 2 3 5 3 4…
File type: application/pdf
Referenced at:
76 Read the precautions on pages 7 to 12 in the introduction before use. Orifice: MMD302: Ø6.3 to Ø10 MMD402: Ø14.7 to Ø16 MMD502: Ø20 MMD34502 Series Chemical liquid manual valve Subject to Export Trade Control Ordinances *Target: MMD402 and 502 only Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range (A -> B) Working pressure range (B -> A) Valve seat leakage Back pressure Ambient temperature Installation attitude Orifice Cv value Chemical liquids, pure water (Note 1) 5 to 90 (Note 2, 3) 1.2 0 to 0.4 0 to 0.4 0 (at, water pressure) 0 to 0.4 0 to 60…
File type: application/pdf
Referenced at:
76 Read the precautions on pages 7 to 12 in the introduction before use. Orifice: MMD302: Ø6.3 to Ø10 MMD402: Ø14.7 to Ø16 MMD502: Ø20 MMD34502 Series Chemical liquid manual valve Subject to Export Trade Control Ordinances *Target: MMD402 and 502 only Specifications Working fluid Fluid temperature Withstanding pressure Working pressure range (A -> B) Working pressure range (B -> A) Valve seat leakage Back pressure Ambient temperature Installation attitude Orifice Cv value Chemical liquids, pure water (Note 1) 5 to 90 (Note 2, 3) 1.2 0 to 0.4 0 to 0.4 0 (at, water pressure) 0 to 0.4 0 to 60…
File type: application/pdf
Referenced at: