2.164 Conversion ratio: inch = ; pounds = = 25.4 453.6 0.4536 mm g Kg 3D d ra w in gs a va ila bl e at w w w .v uo to te cn ic a. ne t CUP HOLDER FIXING SUPPORTS The supports decribed in the following in these pages are made with galvanised sheet steel and they are used to fasten the various types of cup holders to the machine, generally made up of a square tube frame. The screw or the handle with which they are equipped quickly block the support in position. tubular support 30 Art. Tubular section Cup holder Weight g SFP 01 30 mini 160 2 2.165 Conversion ratio: inch = ; pounds = = 25.4 453.6…
File type: application/pdf
Referenced at:
25.4 453.6 0.4536 mm g Kg Conversion ratio: inch = ; pounds = = GAS-NPT thread adapters available at page 1.117 7 7.13 Curve regarding capacity (referring to a 1013 bar pressure) Curve regarding the emptying of a 100-litre volume Curve regarding capacity (referring to the suction pressure) To calculate the emptying time of a volume V1, apply the formula V1 : Volume to be emptied t1 : Time to be calculated (sec) t : Time obtained in the table (sec) Time Time Time Time Vacuum mbar Vacuum mbarVacuum mbar Vacuum mbar Capacity cum/h Capacity cum/h Capacity cum/h Capacity cum/h Curve regarding…
File type: application/pdf
Referenced at:
ezKIT300M Medical Kit Datasheet ezKIT300M Medical Kit © Copyright 2014, ez-Wheel, ezKIT300MEN0512014 ezKIT300M Medical Kit The ezKIT300M medical kit allows to get started with the ez-Wheel ezW300M/W autonomous wheel. It provides an electric assistance to all kind of medical equipment or rolling material used in hospital complex. Kit composition: 1 wheel ezW300M/W 1 wireless tiller head 1 suspension bracket 1 charger 1.8 amperes 1 anti-rotate ring Autonomous wheel ezW300M/W Main specifications Format/diameter 300 mm Nominal power/peak 200 W (S1) Motor specifications Technology Brushless (BLDC…
File type: application/pdf
Referenced at:
ezKIT300M Medical Kit Datasheet ezKIT300M Medical Kit © Copyright 2014, ez-Wheel, ezKIT300MEN0512014 ezKIT300M Medical Kit The ezKIT300M medical kit allows to get started with the ez-Wheel ezW300M/W autonomous wheel. It provides an electric assistance to all kind of medical equipment or rolling material used in hospital complex. Kit composition: 1 wheel ezW300M/W 1 wireless tiller head 1 suspension bracket 1 charger 1.8 amperes 1 anti-rotate ring Autonomous wheel ezW300M/W Main specifications Format/diameter 300 mm Nominal power/peak 200 W (S1) Motor specifications Technology Brushless (BLDC…
File type: application/pdf
Referenced at:
25.4 453.6 0.4536 mm g Kg Conversion ratio: inch = ; pounds = = GAS-NPT thread adapters available at page 1.117 7 7.11 Curve regarding capacity (referring to a 1013 bar pressure) Curve regarding the emptying of a 100-litre volume Time Capacity To calculate the emptying time of a volume V1, apply the formula V1 : Volume to be emptied t1 : Time to be calculated (sec) t : Time obtained in the table (sec) Time Time Time Curve regarding capacity (referring to the suction pressure) Vacuum mbarVacuum mbar Vacuum mbar Vacuum mbar Capacity cum/h Capacity cum/h Capacity cum/h Capacity cum/h Time Vacuum…
File type: application/pdf
Referenced at:
www.suco.de 46 Explosion-protected pressure switches To ATEX standard Technical data 0165 0340 0341 ATEX protection zone: 1 and 2 22 22 Contact rating: max. 1 A / 250 VACmax. 0.25 A / 250 VDC max. 2 A / 250 VAC Temperature range: NBR: -20 °C – +80 °C EPDM: -20 °C – +80 °C FKM: -5 °C – +80 °C Switching frequency: 200 / min. Mechanical life expectancy: 106 cycles Pressure rise rate: ≤ 1 bar/ms Hysteresis: 10 – 30 % (depending on type, non-adjustable) Vibration resistance: 10 g / 5 – 200 Hz sine-wave Shock resistance: 294 m/s2; 14 ms half-sine-wave Cable length: standard length 2 m with wire end…
File type: application/pdf
Referenced at:
www.suco.de 46 Explosion-protected pressure switches To ATEX standard Technical data 0165 0340 0341 ATEX protection zone: 1 and 2 22 22 Contact rating: max. 1 A / 250 VACmax. 0.25 A / 250 VDC max. 2 A / 250 VAC Temperature range: NBR: -20 °C – +80 °C EPDM: -20 °C – +80 °C FKM: -5 °C – +80 °C Switching frequency: 200 / min. Mechanical life expectancy: 106 cycles Pressure rise rate: ≤ 1 bar/ms Hysteresis: 10 – 30 % (depending on type, non-adjustable) Vibration resistance: 10 g / 5 – 200 Hz sine-wave Shock resistance: 294 m/s2; 14 ms half-sine-wave Cable length: standard length 2 m with wire end…
File type: application/pdf
Referenced at:
3 3D d ra w in gs a va ila bl e at w w w .v uo to te cn ic a. ne t 3.13 Conversion ratio: inch = ; pounds = = 25.4 453.6 0.4536 mm g Kg GAS-NPT thread adapters available at page 1.117 3 3.13 Electrical connection Vacuum and compressed air connection These compact and extremely light digital vacuum and pressure switches are enclosed in a sturdy ABS casing. These features allow installation on the machine and close to the application. These digital switches, accurately calibrated and compensated for temperatures, is able to give very precise measurements values. The measured values are shown on…
File type: application/pdf
Referenced at:
25.4 453.6 0.4536 mm g Kg Conversion ratio: inch = ; pounds = = GAS-NPT thread adapters available at page 1.117 7 7.05 1. 2. 1. 2. 1. 2. 3. rotarY vane vacuum pumps – GeneraL description The rotor rotates eccentrically inside a stator and it has grooves in which the vanes move freely and are pushed against the stator inside wall due to the centrifugal force, thus creating as many chambers as the number of vanes. During rotation, the volume of these chambers varies according to their position with respect to the eccentric axis. The chamber volume increase makes the air inside of them expand,…
File type: application/pdf
Referenced at:
25.4 453.6 0.4536 mm g Kg Conversion ratio: inch = ; pounds = = GAS-NPT thread adapters available at page 1.117 7 7.05 1. 2. 1. 2. 1. 2. 3. rotarY vane vacuum pumps – GeneraL description The rotor rotates eccentrically inside a stator and it has grooves in which the vanes move freely and are pushed against the stator inside wall due to the centrifugal force, thus creating as many chambers as the number of vanes. During rotation, the volume of these chambers varies according to their position with respect to the eccentric axis. The chamber volume increase makes the air inside of them expand,…
File type: application/pdf